How to Specify Insulating Blanket Coverage and Fixing for Electrical Work

When purchasing electrical insulating blankets, you should first determine the electrical components to be covered, the actual coverage dimensions, the shape of the equipment, the overlapping method for the blanket panels, and the fastening accessories. For complex equipment or large coverage areas, you also need to confirm whether to use slotted blankets, custom shapes, or a combination of multiple blanket panels. The fastening method should be compatible with the blanket’s structure, and non-conductive fasteners approved by the manufacturer should be used. Selecting a single insulating blanket based solely on the equipment’s dimensions does not guarantee complete and stable coverage of the designated area after installation.

How to Determine the Required Insulating Blanket Coverage

The size of the insulating blanket should be determined based on the actual area requiring protection, rather than simply purchasing it according to the dimensions of busbars, terminals, or equipment enclosures.

Purchasing personnel must first understand the equipment’s structure, the locations of adjacent conductive components, and the areas required to be covered by on-site work procedures.

Identify the Electrical Components Requiring Cover-Up

Different electrical equipment has different structures, so the scope of coverage required also varies.

Vifaa ElectricalMazingatio ya Chanjo
Barabara za basiCover designated busbars and related exposed areas
Kusitishwa kwa CableCover cable terminals and connection points
KubadiliDetermine temporary coverage locations based on the equipment’s internal structure
Viunganisho vya TransformerFocus on connection points and adjacent designated areas
Insulators and CrossarmsDetermine the appropriate coverage method based on the equipment’s outline
Vituo vya UmemeConfirm coverage requirements for terminals and adjacent hazardous areas

For busbars and connection terminals, do not merely measure the length and width of the conductive components themselves; also consider the positional relationships between adjacent components.

For switchgear with complex structures, obtain equipment drawings or on-site photographs in advance to determine the dimensions, shape, and installation method of the insulating blankets.

It is important to note that insulating blankets are temporary insulation covers and cannot replace power shutoff, voltage testing, grounding, isolation, or prescribed safe work procedures.

Calculate the Required Blanket Dimensions

After determining the coverage area, procurement personnel need to further calculate the actual dimensions of the insulating blanket.

For example, the area requiring coverage for a certain piece of equipment is:

KipimoRequired Dimension
Upana wa Ufikiaji700 mm
Urefu wa Ufikiaji900 mm

If a single, complete insulating blanket is used, edge coverage, attachment points, and the equipment’s outline must also be considered.

The following formulas can be used for preliminary sizing:

Required Blanket Width = Coverage Width + Left Allowance + Right Allowance

Required Blanket Length = Coverage Length + Top Allowance + Bottom Allowance

The additional coverage dimensions should be determined based on the equipment structure, the locations of mounting hardware, and approved work procedures; there is no standard allowance applicable to all insulation blankets.

Purchasing personnel should also confirm:

  • Blanket Dimensions.
  • Installation Orientation.
  • Edge Clearance.
  • Eyelet Position.
  • Required Fixing Space.
  • Equipment Geometry.

If the target area contains protruding terminals, support structures, or irregular edges, photographs or dimensional drawings of the equipment should be provided prior to procurement, rather than waiting until after product delivery to perform on-site trimming.

Single-Sheet vs. Multiple-Sheet Coverage

When covering a large equipment area, you may consider using a single large-size insulating blanket or a combination of multiple blanket sheets.

Coverage Methodfaidamazingatio
Single Large BlanketFewer seams; relatively continuous coverageMay be more difficult to handle, position, and secure
Multiple Blanket SheetsAdaptable to different equipment sizes and complex structuresOverlap and connection methods must be confirmed
Slotted BlanketAdaptable to specific protruding structuresSlot positions and product design must be confirmed
Custom-Shaped BlanketAdaptable to special equipment contoursManufacturing and testing requirements must be confirmed

Single-Sheet Coverage is suitable for scenarios where coverage can be achieved with a single blanket sheet and where proper installation and securing are straightforward.

Multiple-Sheet Coverage is suitable for projects with large coverage areas, complex equipment shapes, or those requiring a combination of different-sized blanket sheets.

When using multiple insulating blanket sheets, the following should be specifically checked:

  • Whether there are any uncovered areas between adjacent blanket sheets.
  • Whether the overlap positions can remain stable.
  • Whether specialized Insulating Blanket Clips are required.
  • Whether the fastening accessories are compatible with the blanket’s structure.
  • Whether shifting or curling may occur during installation.

It cannot be simply assumed that reliable coverage is achieved merely by having the edges of two insulating blankets touch. The actual overlap method and dimensions should be determined in accordance with the manufacturer’s instructions and site-approved work procedures.

When Should Buyers Specify Slotted or Custom-Shaped Blankets?

When equipment has protruding terminals, support structures, or special connection components, standard rectangular insulating blankets may not meet installation requirements.

In such cases, consider:

  • Slotted Insulating Blankets.
  • Custom-Cut Insulating Blankets.
  • Special-Shaped Blankets.
  • Project-Specific Cover-Up Designs.

For example, certain equipment requires specific cutouts in the insulating blanket to accommodate the equipment’s structure.

However, slotting and customization should not be simply understood as on-site cutting of existing insulating blankets.

Slot locations, edge construction, material continuity, and electrical performance must all be considered. Any modification that might alter the product’s original structure must be approved by the manufacturer, and it must be verified that the modified product still meets applicable requirements.

Which Fixing Method Should Buyers Specify?

Once the coverage dimensions have been determined, the next step is to select an appropriate fastening method.

The primary function of an insulating blanket fastening system is to help keep the blanket in its intended position, reducing the likelihood of shifting, slipping, or curled edges during operation.

Different insulation blankets may employ different fastening designs; purchasers should not assume that all accessories are interchangeable.

Non-Conductive Eyelets

Eyelets are fastening holes installed along the edges of insulation blankets and can be used to connect approved insulation clamps or other compatible accessories.

Unaponunua, hakikisha yafuatayo:

  • Eyelet Material.
  • Eyelet Diameter.
  • Eyelet Position.
  • Edge Reinforcement.
  • Compatible Fixing Accessories.
  • Mechanical Integrity.

For insulating blankets equipped with eyelets, special attention should be paid to confirming that they are made of non-conductive materials that meet the applicable requirements.

According to IEC 61112, the eyelets and other fastening systems of insulating blankets must meet the corresponding non-conductive requirements.

It should be noted that eyelets are merely fastening interfaces; this does not imply that any metal clamps or standard connectors can be used.

Insulating Blanket Clips

Insulating blanket clips are used to secure insulating blankets; some designs can also be used to connect adjacent blanket sections.

Purchasing personnel should verify:

VipimoNini cha Kuangalia
Nyenzo ya KlipuWhether made of an appropriate non-conductive material
Ufunguzi wa tayaWhether suitable for the blanket thickness
Mtego wa MtegoWhether suitable for the actual mounting location
Eyelet CompatibilityDoes it match the eyelet positions?
Retention PerformanceDoes it maintain a secure hold as designed?
Njia ya KuondoaIs it easy to remove according to the instructions?

It is also necessary to distinguish between accessories designed to secure a single insulating blanket and those designed to connect two blankets.

Not all Insulating Clips offer both of these functions.

Therefore, when purchasing, you should request that the supplier clearly provide the accessory model number, intended use, and accompanying instructions.

Kufunga kwa Ndoano na Kitanzi

Some insulating blankets use Hook-and-Loop Fastening, commonly known as the Velcro-style fastening system.

This design integrates the fastening mechanism into the edges of the blanket panels and is suitable for configurations verified through product design.

Unaponunua, hakikisha yafuatayo:

  • Fastening Strip Material.
  • Non-Conductive Properties.
  • Fastening Position.
  • Edge Construction.
  • Compatibility with Blanket Material.
  • Manufacturer’s Installation Instructions.

Standard commercial Velcro cannot be used as a direct substitute for the specially designed fastening system of these insulating blankets.

The material, installation location, and attachment method of the fastening strips must all comply with the product design requirements.

Manufacturer-Specific Fixing Systems

Some insulating blankets use specialized fastening accessories, such as:

  • Insulating Straps.
  • Dedicated Blanket Clamps.
  • Non-Conductive Fasteners.
  • Integrated Perimeter Fastening.

For project procurement, it is recommended to prioritize the use of complete fixing systems approved by the manufacturer.

It is not recommended to use ordinary metal straps, metal clamps, standard cable ties, or other temporary fasteners as substitutes for the specified accessories without prior confirmation.

How to Determine Fixing Point Positions and Quantity

The number and location of fixing points cannot be determined solely based on the area of the insulating blanket; installation orientation, blanket weight, equipment shape, and site conditions must also be considered.

Horizontal Placement

For horizontal installation, special attention should be paid to whether the insulation blanket can maintain its coverage position.

Purchasing personnel need to confirm:

  • Whether the blanket panels are prone to lateral movement.
  • Whether the edges are prone to curling.
  • Whether the fastening accessories are compatible with the equipment structure.
  • Are there any gaps that could compromise coverage integrity?

Uwekaji wa wima

During vertical installation, the insulation blanket’s own weight may exert continuous force on the fastening system.

Mambo muhimu ya kuangalia:

  • Are the fastening points located at the positions specified by the manufacturer?
  • Are the eyelets and edge construction suitable for this configuration?
  • Do the clamps fit properly with the blanket panels?
  • Is there a risk of slipping or shifting after installation?

Wrapped Coverage

For scenarios requiring the wrapping of specific equipment components, consider the blanket’s shape, wrapping direction, and connection method.

Purchasing personnel must verify:

  • Blanket Dimensions.
  • Wrap Configuration.
  • Edge Position.
  • Fixing System.
  • Equipment Compatibility.

The insulation blanket must not be forcibly stretched, folded, or structurally altered to fit the equipment.

Overlapping Coverage

When using multiple insulation blankets, the fixing points must be coordinated with the overlap locations.

Confirm that the connection method for adjacent blankets is approved by the manufacturer, and check whether any uncovered areas will result after installation.

The following factors may influence the fixing solution:

KiiniEffect on Fixing Design
Blanket DimensionsAffects edge fixing requirements
Blanket WeightAffects the load conditions on the fastening system
Equipment GeometryDetermines available fastening locations
Uelekezaji wa UfungajiAffects blanket stability
Mfiduo wa UpepoOutdoor environments require consideration of wind effects
Maeneo YanayopishanaAffects connection locations and fastener configuration
Mahitaji ya UfikiajiAvoid obstructing necessary operation and inspection points
Approved Fixing MethodSpecifies the fasteners that may be used

The number, spacing, and location of fastening points should be determined by the product design and specific installation conditions. It is incorrect to assume that more fastening points equate to greater safety, as unapproved cutouts or inappropriate fasteners may damage the insulation blanket.

How Do IEC 61112 and ASTM D1048 Apply to Blanket Design?

When purchasing insulation blankets, verify the applicable standards based on material type and project requirements; do not rely solely on the product name to determine compliance.

IEC 61112: 2009

IEC 61112 is a key standard for electrical insulation blankets, primarily covering their classification, materials, construction, and related performance requirements.

Content relevant to the topic of this article includes:

  • Darasa la Umeme.
  • Physical Requirements.
  • Blanket Construction.
  • Non-Conductive Eyelets.
  • Non-Conductive Fastening Systems.
  • Electrical Test Requirements.

This standard permits insulation blankets to take various shapes and designs, including applicable slotted and roll forms.

Therefore, the purchaser may specify different blanket shapes and fastening configurations based on the equipment’s structure, but must ensure that the final product complies with the applicable standard requirements.

ASTM D1048-24

ASTM D1048 is a key product standard for rubber insulating blankets.

Purchasing personnel can verify the following based on project requirements:

  • Darasa la Umeme.
  • Electrical Testing.
  • Ozone Resistance.
  • Tensile Strength.
  • Kurefusha.
  • Tear Resistance.
  • Utulivu.
  • Puncture Resistance.

Please note that ASTM D1048 applies specifically to rubber insulating blankets; its requirements cannot be directly applied to all EVA or other non-rubber materials.

When procuring EVA insulating blankets, you should first confirm the material composition, applicable standards, and corresponding finished product test data.

StandardMtazamo MkuuMazingatio ya Ununuzi
IEC 61112: 2009Electrical insulating blanketsProduct structure, materials, and electrical performance
EN 61112: 2009Relevant European StandardsEuropean Project Technical Requirements
ASTM D1048-24Rubber Insulating BlanketsPerformance and Acceptance of Rubber Insulating Blankets

What Should Be Included in an Insulating Blanket RFQ?

To minimize repetitive communication during the procurement process, customers are advised to provide a complete list of coverage needs and specific requirements at the RFQ stage.

Orodha ya Ukaguzi wa RFQ ya Mnunuzi

Bidhaa ya RFQTaarifa za Kutoa
Blanket MaterialEVA / Rubber / Other specified material
Darasa la UmemeRequired insulation class
Blanket DimensionsRequired length and width dimensions
Eneo la upikiajiActual area to be covered
Aina ya vifaaBusbar / Switchgear / Terminal, etc.
Uelekezaji wa UfungajiHorizontal / Vertical / Wrapped
Coverage MethodSingle Sheet / Multiple Sheets
Mahitaji ya KuingilianaProject-specified overlap requirements
Blanket DesignStandard / Slotted / Custom-Shaped
Vipuli vya machoRequired and specific locations
Fixing AccessoriesClips / Straps / Other approved systems
Viwango vinavyotumikaStandards applicable to the project
Nyaraka zinazohitajikaTechnical Data and Test Reports
wingiKiasi cha Kununua

Orodha ya Ukaguzi wa Nyaraka za Wasambazaji

The supplier shall provide the following based on the actual product configuration:

  • Karatasi ya Data ya Kiufundi ya Bidhaa.
  • Material Specifications.
  • Blanket Dimensions and Drawings.
  • Eyelet and Fixing System Details.
  • List of Compatible Accessories.
  • Maagizo ya Ufungaji.
  • Relevant Electrical Test Reports.
  • Nyaraka Zinazotumika za Uzingatiaji Sheria.

If the customer requires special shapes, slotting, or combinations of multiple blanket sections, they should also provide equipment drawings or on-site photos prior to the quotation.

This allows the supplier to confirm product dimensions, mounting structures, and accessory configurations before production, reducing the likelihood of installation issues after delivery.

Common Insulating Blanket Coverage and Fixing Problems to Avoid

During the procurement process, it is advisable to take preventive measures against the following issues in advance.

Tatizo la kawaidaKinga Iliyopendekezwa
Blanket Size Is Too SmallRe-measure based on the actual coverage area and installation conditions
Coverage Gaps Between SheetsDetermine overlap and connection plans in advance
Incompatible ClipsUse manufacturer-approved accessories
Insufficient Edge StabilityVerify the mounting structure and installation conditions
Incorrect Eyelet PositionProvide dimension drawings before procurement
Unauthorized CuttingDo not cut or drill holes without authorization
Improper Metal FastenersAvoid using unapproved conductive fasteners
Missing Installation InstructionsRequire the supplier to provide product instructions

The most critical issue to avoid is making unauthorized modifications to the insulating blanket’s structure after delivery.

If customers require special dimensions, slot positions, or additional mounting holes, these should be confirmed prior to production, and it must be ensured that the testing and compliance documentation for the final product applies to the delivered configuration.

Conclusion: Specify Coverage and Fixing Before Ordering

The procurement of electrical insulating blankets involves not only materials and electrical ratings but also the need to determine coverage, dimensions, overlap methods, and fastening systems in advance.

For simple equipment, a single standard-sized insulating blanket may suffice; for larger or structurally complex equipment, a combination of multiple blanket panels, slotted designs, or custom shapes may be required.

The fastening system is equally important. Eyelets, insulating clips, and hook-and-loop fasteners must be compatible with the insulating blanket’s structure and comply with the manufacturer’s specified usage guidelines.

JINPOWER offers electrical insulating blankets and related custom configurations, allowing us to determine blanket dimensions, materials, coverage styles, and matching fastening accessories based on project requirements.

If you are procuring insulating blankets for substations, switchgear, or other electrical maintenance projects, we recommend providing equipment dimensions, on-site photos, coverage areas, and fastening requirements when requesting a quote so that we can confirm the appropriate product configuration in advance.

Jaza maelezo yako